Total Sulfur and Nitrogen Analyzer

Combination Total Sulfur & Nitrogen Analyzer HELIOS S&N

Methods : ASTM D5453, ASTM D6667, ASTM D7183, ASTM D7551, UOP 987, IP490, SH/T 0689, ISO 20 846, ASTM D4629, ASTM D6069, ASTM D5762, ASTM D7184, UOP 981, UOP 971, SH/T 0657, ISO 11905

  • HELIOS S&N Total Sulfur and Nitrogen analyzer measures both Sulfur and Nitrogen simultaneously on a single sample.
  • HELIOS S&N analyzer is a combination of 2 detectors that measure Sulfur & Nitrogen without losing their individual performance. 
  • Next generation of 2M detectors.
  • Space and time-saving Sulfur and Nitrogen analyzer.
  • Reduce operator error
  • Reduce consumables and maintenance costs.
  • Measure simultaneously sulfur and nitrogen, or either sulfur alone or nitrogen alone.
  • Robust furnace with 5 years of Warranty
  • Designed to facilitate quick replacement of thermocouple and combustion tube.
  • Sulfur and Nitrogen Analyzer with temperature accuracy better than ±1°C.
  • Low consumption of gases both inert and oxygen.

Helios SN Total Sulfur and Nitrogen analyzer using UV Fluorescence and Chemiluminescence principle.

Fast and automatic measurement of very low levels of sulfur/nitrogen in petroleum products: up to 20 ppb of sulfur and 30 ppb of nitrogen. A liquid injector or Gas / LPG sampler can be used to introduce the sample.

The Eraly Helios SN analyzer measures both Sulfur and Nitrogen simultaneously on a single sample. The Helios SN Total Sulfur and Nitrogen Analyzer provides rapid and accurate measurements of total sulfur using a UV Fluorescence detector and nitrogen using Chemiluminescence. Helios SN analyzes petroleum products, oils, solvents, plastics, synthetic materials, LPG, water, or gases.

Accurate combustion efficiency is crucial for reliable Sulfur and Nitrogen measurements. Helios SN achieves this by precisely controlling the fuel injection and oxidation temperature minimizing soot formation.

Principle of Operation: Chemiluminescence detection based on the reaction of nitrogen oxide (NO) with ozone (O3). The emitted photons are measured by a photomultiplier tube. The next-generation UV Fluorescence detector is up to 20% more accurate for sensitive sulfur measurements.

The Eraly HELIOS SN with innovative features ensures exceptional accuracy and reliable Total Sulfur and Nitrogen Analysis. 

  • Automatic Background Compensation: Eliminate errors caused by fluctuations in chamber pressure, sample pressure, and internal temperature. The HELIOS SN Total Sulfur and Nitrogen Analyzer continuously measures these parameters and automatically adjusts based on calibration values resulting in the highest level of accuracy in Sulfur and Nitrogen measurements.
  • Advanced PM Module: The HELIOS SN utilizes a cutting-edge Photomultiplier (PM) module designed for superior sensitivity and signal stability for consistent results, even for samples with low nitrogen content.Total Sulfur Nitrogen Analyzer Open  
  • Ultra-Wide Detection Range: The HELIOS SN Total Sulfur and Nitrogen analyzer is quite versatile and capable of detecting nitrogen content across a vast spectrum. It can accurately measure extremely low levels, as low as 10 ppb and high concentrations of up to 10% nitrogen content.
  • This new generation sulfur detector utilizes a cutting-edge back-end sensor, resulting in increased sensitivity and up to 20% greater accuracy compared to its predecessor.

 This makes Helios SN suitable for a diverse range of applications eliminating the need for multiple instruments.

Designed to facilitate quick replacement of thermocouple and combustion tube.

Total sulfur analyzer Alarm Functions

    • Total Sulfur Analyzer AlarmIntegrated Diagnostics: The HELIOS SN has a built-in diagnostic system that actively monitors its internal functions. This system detects early signs of potential issues and alerts predictive maintenance before problems arise.
    • Real-Time Alerts: The instrument displays clear and informative alerts directly on the screen, 
    • Comprehensive Service Information: pinpointing with pictures of the specific component or area requiring attention. 
    • Remote Assistance: Eraly’s online support allows for remote monitoring of the HELIOS SN. 

 For each potential issue, the HELIOS SN provides a table displaying the minimum and maximum acceptable values 
alongside the real-time readings. This will assist in making informed decisions about maintenance needs.

Autosampler Options

  • Liquid Automatic Sampler up to 50 positions
  • An automatic sampler for Gas and/or LPG, with 2 injection loops
  • Five to seven positions mini automatic injector for liquid samples
  • Auto boat support for solids samples. 

Mini AutoSampler / Auto-injectorEraly Elemental Anlayzer Mini Auto Sampler

  • Single or 6 positions with waste reservoir and rinsing bottle. 
  • Used for sampling and injecting liquid samples like methanol, petrol ether, ethanol, toluene, naphtha, additives, kerosene, gasoline, diesel, biodiesel, bioethanol, lubricant oil, waxes, and organic solvents.

Gas and LPG Auto Sampler

Gas and LPG autosampler for Elemental analyzers

 

 Compatible with standard: ASTM D6667. 2 sampling loops, one for gas and one for LPG. 

For sampling and injecting Butane, Propane, Methane, Natural Gas, Hydrocarbons and their mixtures (ethylene, methane, calibration gas mixes, etc.).

 

 

AutoSampler – 50 Positions

Early Liquid Autosampler

  • 50-position autosampler with cooling and/or heating options.
  • For sampling and injecting liquids samples like methanol, petrol ether, ethanol, toluene, naphtha, additives, kerosene, gasoline, diesel, bio-oil, lubricant oil, waxes, and organic solvents.
  • The sampling volume is adjustable from 10 μl to 80 μl with adjustable sampling speed.

Specifications of Eraly Helios SN Total Sulfur and Nitrogen Analyzer

Principle Sulur/Nitrogen: UV Fluorescence / Chemiluminescence
 
Methods :
 ASTM D5453, ASTM D6667, ASTM D7183, ASTM D7551, UOP 987, IP490, SH/T 0689, ISO 20 846 ASTM D4629, ASTM D6069, ASTM D5762, ASTM D7184, UOP 981, UOP 971, SH/T 0657, ISO 11905
 
Detection Limit:5 ppb S / 5 ppb N to 10%
Quantification:10 ppb S / 10 ppb N to 10%
 
Accuracy S/ RSD S:
At 0,1 ppm : 0,48 %
At 1 ppm : 0,32 %
At 100 ppm : 0,84 %
 
Accuracy N / RSD N:
At 0,1 ppm : 0,51 %
At 1 ppm : 0,40 %
At 100 ppm : 0,88 %
 
Injections :
20 to 80 µl liquids | 10ml gas | 20µL LPG
 
Supply Gas:
Oxygen : 99,998% – 3 bar
Argon : 99,995 % – 3 bar
 
Power :
110 V / 230 V
60Hz – 50 Hz
800 W
 
Temperature :
Furnace F2 up to 1100°C
Furnace F1 programmable 25 to 980°C

 

Eraly HELIOS SN Total Sulfur and Nitrogen Analyzer caters to various applications and industries due to its versatility and exceptional performance.  

Helios SN using the UV Fluorescence and  Chemiluminescence principle detects Sulfur and Nitrogen in liquid, oil, biofuel, lubricating oil, solvent, water, gas, LPG and solid samples.

  • Petroleum refining
  • Environmental monitoring
  • Quality control in fuel production
  • Research and development
  • Environmental analysis
  • Agricultural applications: Measuring nitrogen content in soil, fertilizers, and plant tissues.
  • Pharmaceutical industry
  • Lubricants

Related PRODUCTS