Hiranuma Automatic Potentiometric Titrator COM-A19 Series
Automatic Potentiometric Titrator COM-A19
Hiranuma Automatic Titrator COM A-19 brings you the flexibility you need.
The user-friendly Automatic potentiometric titrator COM-A19 Series titrators can be used for a wide range of applications.
- Large 8.4-inch Color LCD Touch Panel with adjustable display angle
- Two simultaneous titrations can be performed.
- 128,000 steps Burette resolution
- 10 segment LED light bar Stirrer speed indicator
- 3 colours LED Stirrer state indication
- Continuous positive/negative rotation Stirrer rotation mode
- Built-in Thermal Printer
- USB/LAN interface
- 8 steps Built-in speaker volume
The Hiranuma automatic titrator COM-A19 Series provides you with the flexibility for your titration needs. Japans leading manufacturer Hiranuma with over half a century of experience in the manufacturing of automatic titration instruments with its latest COM-A19 series presents the most flexible and easy to use potentiometric titrator for a wide variety of applications.
Two Types of Titration in Parallel
Two types of titration can be carried out simultaneously by adding a titration station and a stirrer.
Easy Burette Head Replacement
Burette head can easily be removed just with one hand together with a reagent bottle by simply sliding it towards the user.
This is particularly useful if using multiple burette heads. User can easily manage different titrant by simply switching them.
Economical Purge Function
- Reagents can be automatically replaced, which greatly reduces fluid wastage.
- Discharging / charging at the top end of the syringe is repeated.
- The number of economical purge cycles can be set from 1 to 99.
Multiple layer user settings
Different user levels can be set to improve security by restricting inadvertent usage.
Large Color LCD Touch Panel
A large 8.4″ touch panel screen ensures an easy user interface like entering parameters for tests and selecting menu options. Provided with a replaceable protective film to protect the screen from scratches and wear over the long term.
LCD Display Adjustable in 16 Positions
Each user can adjust the angle of viewing for their convenience. The position can be locked so that it will not move when the screen is pressed.
Status Indicator with 3 LED Colors
Colored lights allow the user to confirm the status of the operation from a distance. The user will also be alerted to unexpected problems right away.
40 stirrer Rotation Speeds Can Be Set
Rotation can be adjusted manually in fine increments shown by LED bars—it is easy to see and understand. (Four increments per bar)
USB/LAN Port
Approximately 9,900 results can be stored on a USB memory stick. With optional software, the user can view the data on a PC or use a recalculation function. With a LAN connection, the user can also view the data on a Web browser.
Built-in Thermal Printer
Equipped with a built-in thermal printer with a paper roll 58 mm wide, which can be set up simply by inserting the paper roll and closing the cover.
The specifications for Hitachi Hiranuma automatic titrator COM-A19 as belo1w.
Main Unit | |
Parallel measurement | Up to 2 titration stations are connectable. (with optional titration station (and stirrer)) |
Titration method | Potentiometric titration |
Measuring range | pH: 0 to 14, mV: -2000 to +2000 mV |
Titration mode | Learn titration, Inflection-point detection, Set-point detection, Set point/Inflection-point detection, Cross-point (F, B, V1, V2) detection, Neutralization values in petroleum products (Oil1, 2) Other functions: pH-Stat (1, 2), pH measurement, Dispensing, Calculation, pKa measurement |
Endpoint detection mode | Auto-detection using a second derivative (with smoothing function), Set-point detection, Cross-point detection |
Number of endpoints detected | Up to 5 end points with a Learn titration file or linked method files |
Display | 8.4 inch color LCD touch panel |
Displayed content | Titration conditions, Data per drip, Titration results, Titration curve, Differential curve, List of titration results, Statistics calculation results, Condition settings display, Real-time display of fluid temperature during titration (when thermistor electrode is connected) |
Memory data capacity (Each titration station) | Built-in memory: 100 data points |
Settings input method | USB flash memory: (≧256MB) Maximum capacity approx. 9,900 data points |
Sample data | Key touch input |
Master file | Sample No.: 2 digits, ID code: 16 alphanumeric characters |
Conditions file | Titration execution files: 51 files |
Number of linked condition file | 51 files (method parameters, constant files, control mode files) |
Titration control mode file | 9 files (up to 5 files in case of titration files linkage) Standard files: 51; Neutralization value files in petroleum products: 51; Manufacturer settings modes (0–11), Blank modes (12–19), User setting mode (20–50) |
Constant file (settings parameter of concentration calculation constant) | 51 files K, L (constants), F (factors), M or N (molarity or normality), B (blank mL), S (sample size), T (temperature °C) |
Sample files | 99 files (Sample No., ID code, Master file and Sample size) |
Auto input function | Function to automatically set titration results to constant parameters (blank, factor, etc.) . Condition files for automatic input can be designated. |
Calculation function | Concentration calculation, Statistics calculations, pH automatic compensation |
Branching function | After measuring the potential prior to titration, branching into maximum 2 condition files |
GLP-compliant function | 1) Buret precision check, 2) Electrode check, 3) Buret use frequency (display/print), 4) Electrode maintenance (display/print), 5) Reagent level display and alarm |
Printer | Built-in thermal printer (Paper roll width: 58 mm) |
External input/output | RS-232C: 1 port (For balance or computer connection), LAN: 1 port, USB flash memory stick: 1 port |
Power supply | AC100-240 V±10 % 50/60 Hz 60 VA (MC-3000 only) A power cable is not included in this product. (*1) |
Dimensions / weight | 235(W) × 400(D) × 250(H) mm / Approx. 6.5 kg (MC-3000 only) |
TS-3000 Titration Station | |
Buret capacity | Standard: 20 mL transparent syringe (with UV light shield protective cover) Can be replaced with 5, 10, 50 mL buret head (optional) |
Forming system | Vacuum forming |
Wetted part material | PTFE, hard glass, ceramic ( Hydrogen fluoride cannot be used.) |
Connecting tubes | φ2 x φ3 PTFE tube (brown) |
Reagent bottle size | 500 mL |
Valve switching | Automatic switching by ceramic lapping |
Discharge speed/ Absorption speed | Full stroke: minimum 50-second (min. 25-sec. for discharge or absorption) Can be set from 50 to 250 seconds in 25-second increments (with a 20-mL syringe) |
Minimum drip volume | 0.00125 mL (with 20-mL syringe) |
Buret accuracy | Relative accuracy: ±0.1% or less (with full capacity discharge from 20-mL syringe at factory settings (new)) Repeat accuracy: 0.01 mL or less (with full capacity discharge from 20-mL syringe, n=6 standard deviation) |
Buret attachment | Up to two B-3000 burets can be attached simultaneously |
Measurement unit attachment | Only the S-3000 can be connected |
Power supply | AC100-240 V±10 % 50/60 Hz 70 VA |
Dimensions / weight | 120(W) × 340(D) × 470(H) mm / Approx. 6.5 kg (When measurement unit and burette head are attached.) |
K-3000T Stirrer | |
Beaker size | Up to 500mL |
Stirring system | Magnetic stirrer |
Stirring bar | PTFE (φ8 x 30 mm): 1 included |
Rotation speed setting | Adjustable – Initial speed can be set on the main controller unit |
Number of attachment to electrode holder | Electrodes: 2 Thermistor electrodes: 1 Buret tips: 3 |
Power supply | DC12 V (supplied by titration station) |
Dimensions / weight | 100(W) x 165(D) x 345(H) mm / Approx. 1.5 kg |
Operating Environment |
・ Temperature: 5–35 °C |
・ Humidity: 45–85% with no condensation |
・ Atmosphere: No presence of acid, alkali, organic solvent gas, or rare gas |
・ Other: No inordinately high amount of dust or particles. |
・ No equipment nearby that generates strong lines of magnetic force. |
See below applications for Hiranuma Automatic Titrator COM-A19. For other applications please contact us.
Food |
Salt content in soy sauce |
Successive measurement of acid and salt in dressing |
Continuous measurement of citric acid and vitamin C in soft drink |
Continuous measurement of acid (citric acid) and amino nitrogen in grapefruit juice |
Acid value of cooking oil |
Iodine value measurement for cooking oil |
Saponification value of cooking oil |
Peroxide value measurement for cooking oil |
Acid value measurement of orange juice |
Measurement of vitamin C in soft drink with indophenol method |
Drugs and Medicines |
Determination of sodium acetate with perchloric acid titration |
Available iodine in mouthwash (Povidone-iodine) |
Sodium chloride in peritoneal dialysis solution |
Purity determination for papaverine hydrochloride by perchloric aid titration |
Standardization of perchloric acid in acetic acid with potassium hydrogen phthalate |
Quantitative determination of sodium citrate |
Detergents・Bath additives・Cosmetics |
Determination of anion surfactant in detergent |
Quantitative determination of sodium sulfate in bath additive |
Standardization of benzethonium chloride standard solution |
Environment |
Quantitative determination of chloride ions in tap water |
Total hardness in tap water |
Calcium hardness in tap water |
Determination of residual chlorine in tap water |
Determination of alkalinity in bottled water |
Plating & Etching solution |
Quantitative determination of nickel chloride in nickel plating solution |
Quantitative determination of chromic anhydride and chromium (III) in chromium plating solution |
Determination of Tin (Sn²⁺) in solder plating solution |
Determination of hydrogen peroxide and sulfuric acid in etching solution |
Quantitative determination of total nickel (Ni²⁺) in nickel plating solution |
Determination of copper in copper sulfate plating solution |
Electric & Electronics |
Determination of alkaline component in photoresist remover solution |
Determination of alkaline component in photoresist remover solution |
(Determination of carbonates with barium chloride addition method) |
Metals |
Quantitative determination of zinc ion |
Determination of trace chloride ion in copper sulfate solution |
Determination of ferrous and ferric ion in steel cleaning solution |
Quantitative determination of manganese ion |
Quantitative determination of lead ion |
Quantitative determination of copper ion in plating solution |
Soda Pulp Industry |
Purity determination of sodium hydroxide |
Fractional determination for mixture of sodium hydroxide and sodium carbonate |
Determination of available chlorine in sodium hypochlorite |
Determination of residual alkali in sodium hypochlorite |
Determination of sodium chloride in sodium hypochlorite |
Inorganic acids & Mixed acids |
Purity determination of sulfuric acid |
Purity determination of phosphoric acid |
Fractional determination of hydrochloric acid and sulfuric acid |
Fractional determination of nitric acid and acetic acid |
Determination of boric acid in plating solution |
Fractional determination of nitric acid and phosphoric acid |
Organic acid |
Determination of formic acid |
Purity determination of citric acid |
Determination of lactic acid |
Purity determination of oxalic acid |
Fractional determination of acetic acid and ammonium acetate |
Fractional determination of ascorbic acid and sodium ascorbate |
Fractional determination of hydrogen peroxide and peracetic acid |
Lubricant petroleum products |
Acid number in Lubricating oil |
Base number in lubricating oil (Hydrochloric acid method) |
Base number in lubricating oil (Perchloric acid method) |
Acid number in Refrigerating machine oil |
Base number in Lubricant oil (Perchloric acid / Back-titration) |
Resins |
Epoxy equivalent determination of epoxy resins |
Determination of isocyanate (NCO) content in adhesives |
Cement Concrete |
Determination of chloride ion in cement |
Determination of chloride ion in concrete |