Rigaku NEX CG II ED XRF Analyser
Unmatched Sensitivity in EDXRF NEX CG II
- ED XRF Analyzer Conforms to ASTM D7751, ASTM D5059, ASTM D4929, ASTM C114, EPA Tier 3, and more
- Non-destructive elemental analysis from sodium (Na) to uranium (U)
- Advanced 3D Cartesian geometry for ultra-low detection limits
- Indirect excitation with secondary targets for superior sensitivity
- Large-area, high-throughput silicon drift detector (SDD)
- Rapid, multi-element analysis of solids, liquids, powders, coatings, and thin films
- Powerful QuantEZ® and RPF-SQX software for qualitative and quantitative analysis
- Automated sample handling with multiple autosampler options
- Analysis in air, helium, or vacuum for enhanced light element sensitivity
- 2-year warranty and robust construction for industrial reliability
The Rigaku NEX CG II Series is a breakthrough ED XRF Analyzer engineered for laboratories and industries demanding the highest sensitivity, reliability, and flexibility in elemental analysis. Leveraging advanced energy dispersive X-ray fluorescence technology, the NEX CG II delivers rapid, non-destructive, multi-element measurements from trace to percent levels across an unmatched range of sample types—including oils, liquids, solids, metals, polymers, powders, pastes, coatings, and thin films.
Advanced 3D Cartesian Geometry for Superior Performance
Unlike conventional XRF systems, the NEX CG II employs a unique close-coupled 3D Cartesian Geometry optical kernel with secondary target excitation. This design dramatically increases the peak-to-background ratio, achieving exceptionally low detection limits—even in challenging matrices such as water, hydrocarbons, and biological materials. The result is precise trace element analysis, critical for industrial quality control, environmental monitoring, and advanced research.
Indirect Excitation & High-Throughput Detection
The indirect excitation system uses monochromatic and polarized secondary targets to eliminate background noise and improve detection limits. The large-area SDD (silicon drift detector) ensures high count rates, superior peak resolution, and the lowest possible limits of detection for both major and trace elements.
Intuitive Software & Automation
NEX CG II is powered by QuantEZ® software, providing intuitive instrument control, customizable methods, and streamlined routine operation. The RPF-SQX Fundamental Parameters software enables both semi-quantitative and rigorous quantitative analysis, reducing the need for expensive calibration standards and lowering cost of ownership. Automated sample handling options, including changers for up to 52 mm samples and sample spinners, maximize throughput and accommodate non-uniform or large samples.
Flexible Analysis Environments
With analysis possible in air, helium, or vacuum, the NEX CG II delivers superior light element sensitivity and is adaptable to a wide range of sample types and laboratory environments. Detector protection features and robust construction ensure reliable, long-term operation.
Industry-Leading Applications
From industrial and in-plant quality assurance to research and development, the NEX CG II is ideal for:
- Agricultural soils and plant materials
- Finished animal feeds
- Waste oils and lubricants
- Environmental samples (air, water, soil)
- Pharmaceuticals and cosmetics
- Cement, coal fly ash, rare earth elements, and more
Compliance & Test Methods
The NEX CG II conforms to major international standards and methods, including:
- ASTM D7751 (Lube Oils)
- ASTM D5059 (Pb in Gasoline)
- ASTM D4929 (Organic Chlorides in Crude)
- ASTM C114 (Cement)
- EPA Tier 3 (Gasoline)
- S. EPA Sensitivity for Air Filters
- ASTM D8252 (Metals in Crude and Resid)
- ASTM G65, G105, B611 (legacy and comparative applications)
Why Choose NEX CG II?
- Industry-best detection limits for trace and major elements
- Multi-purpose, multi-element analysis in a single instrument
- Low cost of ownership with reduced calibration requirements
- Easy to use for all operators, from routine QC to expert R&D
- Backed by Rigaku’s global support and a 2-year warranty
Feature | Specification |
| Technique | Indirect excitation energy dispersive X-ray fluorescence (EDXRF) |
| Elemental Range | Sodium (Na) to Uranium (U) |
| X-ray Tube | 50 kV 50 W (NEX CG II), 65 kV 100 W (NEX CG II+) Pd anode |
| Detector | Large-area, high-throughput silicon drift detector (SDD) |
| Geometry | 3D close-coupled Cartesian Geometry optical kernel |
| Excitation | Five secondary targets (monochromatic/polarized) |
| Sample Types | Solids, liquids, powders, coatings, thin films |
| Analysis Environment | Air, helium, or vacuum |
| Software | QuantEZ® (control & analysis), RPF-SQX FP, SureDI (21 CFR Part 11) |
| Autosampler Options | 15-position (32 mm), 10-position (40 mm), 9-position (52 mm), spinner |
| Sample Chamber Size | Up to 32.5 cm diameter × 7.5 cm height |
| Power Requirements | 100–240 V, 3.8–1.6 A (50/60 Hz) |
| Dimensions (W × D × H) | 46.3 × 49.2 × 38.2 cm |
| Weight | ~65 kg (NEX CG II), ~68 kg (NEX CG II+) |
| Warranty | 2 years |
The Rigaku NEX CG II Series is designed for rapid, accurate elemental analysis in a wide range of industries and research environments. Its versatility and sensitivity make it the analyzer of choice for:
- Industrial Quality Control:Routine analysis of raw materials, finished products, and process streams in manufacturing, petrochemicals, cement, and metals industries.
- Environmental Monitoring:Detection of trace elements in air, water, soil, and waste for regulatory compliance and pollution control.
- Agriculture & Food:Analysis of soils, fertilizers, plant materials, and animal feeds for nutrient and contaminant levels.
- Energy & Fuels:Testing of oils, lubricants, gasoline, diesel, coal fly ash, and rare earth elements for quality and specification compliance.
- Pharmaceuticals & Cosmetics:Quality assurance and trace contaminant analysis in production and R&D.