Compact Cloud and Pour Point Bath
Compact cloud and pour point bath for ASTM D97 testing K66100
- Manual cloud and pour point bath for determining cloud point and pour point of fuels, lubricants, crude oils, and other petroleum products.
- Conforms to ASTM D2500 (cloud point) and ASTM D97 (pour point) with additional conformity to ASTM D5853 and related IP methods.
- Compact, space-saving design suited to tight bench-top environments.
- Solid-block bath design described as minimising temperature gradients for reliable manual testing.
- Extreme low temperature capability with jacket temperature reaching down to -105°C.
- Stated temperature range -105 to +6°C, with reheating to 24°C.
- Pre-set CPP temperature steps provided for cloud and pour point specifications.
- Meets step transition requirement: ≤5 minutes per step down to -51°C, supporting efficient stage transitions.
- Designed to prevent ice issues: no ice build-up on the top cover.
- Supplied as a turnkey solution with four complete cloud and pour point test tube assemblies.
- Compact footprint
A compact cloud and pour point bath built for extreme low-temperature manual testingThe K66100 Manual Compact Cloud and Pour Point Bath is a cloud and pour point bath designed for the precise manual determination of cloud point and pour point for petroleum products, fuels, lubricants, and crude oils.
It is positioned as a space-saving, solid-block bath, providing standards-compliant testing performance where bench space is limited.For laboratories running routine and investigative cloud and pour point test work, the K66100 focuses on practical outcomes that matter at the bench: controlled step temperatures, rapid stage transitions to key low-temperature points, and reduced ice-related interruptions.ASTM method alignment (ASTM D97 / ASTM D2500 / ASTM D5853) with related IP stepsThe K66100 conforms to ASTM D2500 (Cloud Point), ASTM D97 (Pour Point) and ASTM D5853, and it is also listed as conforming to related IP methods IP 15, IP 441 and IP 219.
This makes it suitable for laboratories that need a manual ASTM D97 bath workflow and an ASTM D2500 cloud point bath arrangement in a compact footprint.Extreme low temperature capability with controlled reheatingA key requirement in cold-flow testing is stable operation at very low temperatures. The K66100 is specified with a temperature range of -105 to +6°C, and it includes a reheat to 24°C capability.
The datasheet also states that the jacket temperature can reach down to -105°C, supporting extreme low temperature testing needs for fuels and lubricants.Pre-set temperature steps to support consistent stage-based testingTo support repeatable manual stage progression, the K66100 provides pre-set temperature steps for cloud and pour point specifications.
The listed CPP temperature steps (°C) are: 6, 0, -18, -33, -51, -69, -87, -105.
For CFPP the listed steps (°C) are: 0, -17, -34, -51, -67, -85.2.
This helps laboratories maintain consistent stage temperatures during a cloud and pour point workflow without relying on external step programming.Fast step transitions aligned to method expectations down to -51°CThroughput and workflow consistency often hinge on how quickly a bath transitions between stages. The K66100 is specified to meet step transition time requirements of five minutes or less per step down to -51°C, stated as meeting step transition time to the automatic method requirement.
This supports efficient movement through key stages without extended waiting periods, while keeping the simplicity of a manual bath approach.Solid-block design and ice control to reduce routine disruptionsThe Petro‑Online article describes the solid-block bath design as minimising temperature gradients and improving reliability in routine use.
The datasheet also explicitly states “No ice building on the top cover”, and the article highlights elimination of ice build-up on the top cover to reduce routine maintenance.
For day-to-day testing, this focus on ice control can reduce interruptions that typically slow manual cold-flow work.Turnkey configuration supplied with four test assembliesThe K66100 is supplied as a turnkey solution and includes four complete cloud and pour point test tube assemblies, supporting quicker commissioning and fewer gaps at installation.
Included assemblies are specified as: K77000-2 Pour Point Test Vessel, K77000-03177 Cork, K66100-11 Cloud and Pour Point Head, and 504-000-024 O-Ring.Practical installation details for lab planningFor lab utilities, the K66100 specifies 90–264V, 47–63Hz, 2.5A max, which supports common laboratory power supply ranges.
Its physical dimensions are 30.5 cm × 27 cm × 48.5 cm, with a weight of 16 kg, making it suitable for bench-top integration in space-limited environments.
| Item | Specification |
| Product | K66100 Compact Cloud & Pour Point Solid Block Bath |
| Methods | ASTM D97, ASTM D2500, ASTM D5853 |
| Related methods | IP 15, IP 441, IP 219 |
| Sample types | Fuels, lubricants, crude oils, other petroleum products |
| Temperature range | -105 to +6°C (Reheat to 24°C) |
| CPP temp steps (°C) | 6, 0, -18, -33, -51, -69, -87, -105 |
| IP 219 temp steps (°C) | 0, -17, -34, -51, -67, -85.2 |
| Temperature accuracy | ±0.5°C |
| Step transition time | ≤5 minutes per step down to -51°C |
| Ice control | No ice building on the top cover |
| Electrical | 90–264V, 47–63Hz, 2.5A max |
| Dimensions (W×D×H) | 30.5 × 27 × 48.5 cm |
| Weight | 16 kg |
| Included accessories | K77000-2 Pour Point Test Vessel, K77000-03177 Cork and 504-000-024 O-Ring. |
| Ordering | Catalog no. K66100 (115/230V, 50/60Hz) |
The K66100 is designed for laboratories requiring reliable manual cloud and pour point determination across petroleum products, especially where bench space is limited and low-temperature performance is critical.
Typical uses include:
- Manual cloud and pour point test work for fuels.
- Manual ASTM D97 pour point testing for lubricants.
- Low-temperature cloud and pour point work for crude oils and other petroleum products.
- Expanding cold-flow testing capacity in crowded laboratory environments or mobile labs without significant infrastructure changes