Automatic Cleveland Open Cup Flash Point Tester

ASTM D92 COC open cup flash point tester K72000

Methods : ASTM D92; IP 36, 403; ISO 2592; AFNOR;T60-118; EN 22592; DIN 51376

  • Fully automated Cleveland Open Cup Flash Point Tester
  • Conforms to ASTM D92 and related specifications
  • User-friendly interface with integrated 10.4” touchscreen
  • High-precision temperature control and measurement
  • Automatic barometric pressure correction
  • Robust design for laboratory environments
  • Advanced safety features like a Fire suppression system with inert gas
  • Equipped with Emergency Safety Switch
  • Quick and easy calibration
  • Real-time data logging and export options
  • Compact and efficient design
  • Dual fan cooling system for rapid testing cycles
  • Suitable for all petroleum products except fuel oils with open cup flash points below 79°C

The Koehler Automatic Cleveland Open Cup Flash Point Tester K72000 is an advanced instrument designed to determine the flash and fire points of petroleum products per ASTM D92 standards. It features a fully automated operation, which minimizes user intervention and ensures consistent and accurate results. User-friendly touchscreen interface allows easy operation and monitoring of test parameters for both novice and experienced users.

The K72000 COC Open cup flash point model boasts high-precision temperature control, ensuring accurate and repeatable measurements. It includes automatic barometric pressure correction to account for atmospheric variations, enhancing the reliability of the test results.

The robust design makes it suitable for demanding laboratory environments, while its advanced safety features ensure safe operation. The instrument is equipped with a fire suppression system that floods the unit with inert gas in the event of a fire, providing an additional layer of safety. Emergency Safety Switch for immediate shutdown in emergencies.

How Does It Work?

This automatic Cleveland open cup flash point tester uses an open cup method to determine the temperature at which a flammable liquid produces enough vapor to ignite. The process includes:

  • Sample Preparation: A small amount of the substance is placed in the designated cup.
  • Temperature Control: The system heats the sample incrementally, maintaining precise heating rates as per the method.
  • Ignition Sequence: An automated mechanism introduces the flame at regular intervals until ignition occurs.
  • Data Recording: Flash and fire points are recorded digitally, eliminating guesswork and manual errors.

This seamless automation not only enhances productivity but also reduces operator fatigue, making it a preferred choice over traditional manual methods.

Calibration is quick and straightforward, and the instrument offers real-time data logging with options to export data for further analysis. The compact design of the K72000 makes it an efficient addition to any laboratory, saving valuable bench space without compromising performance.

  • Automation and Precision: The K72000 offers fully automated flash point detection, ensuring precise and repeatable results.
  • Enhanced Safety Features: The device includes over-temperature protection and automatic flame extinguishment for maximum operator safety.
  • 10.4” Touchscreen Interface: A large, high-resolution touchscreen interface simplifies operation and enhances usability.
  • Data Management: The tester provides real-time data visualization and export options, making it easy to log and analyze results.
  • Time Efficiency: Faster heating and cooling cycles allow for higher testing throughput, reducing laboratory downtime.

 

Why is It Essential for ASTM D 92 Compliance?

ASTM D 92 is a globally recognized standard method for determining the flash point of petroleum products using the Cleveland Open Cup method. Compliance with this standard ensures that your laboratory meets regulatory requirements and produces reliable, accurate results. The Koehler K72000 is explicitly designed to meet these stringent standards, making it the ideal choice for industries that prioritize quality and safety.

The system software runs on an integrated processor PC with the latest Windows operating system, and the 10.4” touchscreen interface displays all operator parameters and results on a single screen.
Results can be stored on the local hard drive, ensuring easy access and retrieval of test data. The integrated Dual Fan System directly cools the test cup and the environment around the cup, maintaining optimal testing conditions. The robust design and state-of-the-art technology make the K72000 automated Cleveland open cup flash point tester a reliable and durable choice for flash point testing.

The Specifications of  Automated Cleveland Open Cup Flash Point Tester K72000

SpecificationDetails
Test MethodASTM D 92, IP 36, IP 403, ISO 2592, AFNOR T60-118, EN 22592, DIN 51376
Sample Cup TypeCleveland Open Cup
Temperature RangeAmbient to 400°C
Temperature Accuracy±0.1°C
Heating RateProgrammable (2–17°C/min)
Ignition SourceElectric or gas flame
Automation LevelFully automatic
Data OutputUSB, Ethernet, or cloud-based export options
Display10.4” Touchscreen interface
Safety FeaturesOver-temperature protection, automatic flame-off
Power Requirements110V/220V, 50/60Hz
DimensionsCompact, bench-top design
Weight15 kg

The Koehler Automatic Cleveland Open Cup Flash Point Tester is a versatile tool used across multiple industries to ensure the safety, quality, and compliance of flammable materials. From assessing the flash points of crude oil derivatives to evaluating the thermal stability of lubricants, this COC flash point tester plays a critical role in modern laboratories.

Petrochemical Industry:
  • Assessing flash points of gasoline, diesel, kerosene, and heavy oils.
  • Ensuring compliance with ASTM D92 and other international standards.
Lubricant Manufacturing:
  • Evaluating the thermal stability and volatility of motor oils and greases.
  • Supporting quality control processes for automotive and industrial lubricants.
Chemical Processing:
  • Volatility assessment of solvents, paints, and adhesives.
  • Hazard classification for chemical storage and transportation.
Transportation Fuels:
  • Quality assurance for aviation fuels, marine bunkers, and biofuels.
  • Meeting regulatory requirements for fuel safety and performance.
Environmental Testing:
  • Hazard classification of waste materials and spills.
  • Supporting environmental compliance and risk management initiatives.
Research & Development:
  • Developing new fuel formulations and chemical compounds.
  • Conducting pilot studies and material evaluations.

By leveraging the capabilities of the Koehler K72000, organizations can achieve higher levels of safety, efficiency, and compliance.